VishalMistry
4th September 2017, 15:10
Hi all,

I was wondering if there is any standard dll which identifies active bom BOM components. If we pass it Manufac.Item,Position and Sequence number.

Vishal

mark_h
4th September 2017, 17:24
Are we talking date or unit effectivity? There might be some DLL's but I believe we wrote most of our own. Will have to check once I get back to work.

VishalMistry
5th September 2017, 10:33
Hello Mark,

I am talking about date. We also use custom logic to determine if component is active or not but I was wondering if there is any standard DLL.

Vishal

mark_h
5th September 2017, 14:20
Check out function itibom0002 - we use one routine out of it. But it looks like only to get the retrieval date. Other than that, we use our own code to determine if it is active. Sorry no DLL's used in our code, so not sure there is one.

mark_h
5th September 2017, 17:07
Check out the otibomdll010 library. It has tibom.dllb010.check.component.effectivity.date and and tibom.dllb010.component.effective routines included in it. I do not think we used these anywhere, but it looks like we do use the tibom.dllb010.get.quatity.by.effectivity routine.

VishalMistry
6th September 2017, 16:45
Hello Mark,

The library is not present in our environment. BTW, I have done it through custom logic.

Vishal

mark_h
7th September 2017, 15:39
Interesting - I did just notice this is in our A&D VRC we get from infor.