günther
14th August 2002, 09:45
Hi folks.

I discovered a problem I've never seen before. For a session that was developed some time ago, I had to modify a report script. Now the session runs without any problems from the gui (bw6.1), but when the session is started from ascii (ba6.1), an error screen is displayed:

Error [BaFindObjectInProcess ]: Process 1: objekt 0 not found
Error [BaChangeWindow ]: Process 1: objekt 0 not found

press any key to remove this window

and then

ba6.1: the logfile has been updated with 2 message(s)

Any ideas?

patvdv
14th August 2002, 10:37
I have seen a similar error appear when some of the objects in $BSE/application sub-directories had wrong permissions and/or ownerships.

günther
14th August 2002, 10:48
The problem was simply a refresh() call inside the before.program section ...