simona
25th June 2008, 12:05
Hello there,

I imported, by mistake, sessions (with forms, reports, and scripts) in wrong VRC (B61U-a-lvd). I imported again the components in the right VRC (B61U-a-rom), but now I have to delete the components from first VRC (B61U-a-lvd).
[B61U-a-lvd is derived from B61U-a-rom]

In this machine I don't have the Development rights and I cannot access session ttadv3530m000 (Reports). In that case I deleted reports from tools tables ttadv330-ttadv337 with VRC B61U-a-lvd.
When I'm printing one of those reports I still see the wrong version, imported first time in a wrong VRC, that means the that was not enough to clean the tables ttadv330-337.
There is any way to clean the reports from the VRC B61U-a-lvd ???

The same problem is for Scripts, I deleted from tools table ttadv230 scripts with VRC B61U-a-lvd. (Probably for scripts is enough this action.)

Thank you very much in advance.

Simona

zardoz
25th June 2008, 12:15
Removing scripts/reports from ttadv tables doesn't solve your problem (and it's potentially dangerous :) ).

The objects of the reports and scripts are always present (and still used by bshell), you have to remove them from $BSE/application directories.

In particular:
$BSE/application/PPB61U-a-lvd/oMMM (directories of the scripts object)and
$BSE/application/PPB61U-a-lvd/oMMML (directories of the report object

where PP is the package
MMM is the module
L is the language

Han Brinkman
25th June 2008, 12:35
No development rights means you can not use ttadv6250m000?