learner
22nd January 2003, 08:56
Hello,

I am running a customized session and when i select the device type as ASCIF and give the path of the pc where the file is to be genereted as
\\10.10.30.19\c\test.txt
It gives me the following error

1. Process 18: Error : Read Row Error 506 on ttadv330900 (error 0)
2. Process 18: Fatal Error : Error 506 (Table does not exist)on SELECT
3. Process 18: Fatal Error : Cannot continue in ttstpconv in DLL : ottdllvrcsearch (get.company)


please note that this pc hard disk C is full shared without a password, and then i gave the device type as Display ( D ) and ran the session again and this time it give proper output and then i went into Device mainatince and selected session Maintain Device Queue ( ttaad3120m000 ) and clicked on Repeat Request and now again i gave the following path \\10.10.30.19\c\test.txt now this time the file got genereted without any error ....please explain me what is the problem ?
why the device type as ASCIF not working when i do it with my cusomized session and why does it works with Maintain Device Queue ??

I tried with one more customized session also .....but same thing happens.

Waiting for your reply

HeikeF
23rd January 2003, 16:10
Hi,

run create tables for the company 900.

BaaN is missing a table.

Regards

Heike

learner
23rd January 2003, 17:44
Ok, i will try for this.

but tell me through which session i can run this option ?

NPRao
23rd January 2003, 18:36
BaaN Tools do not support printing options with an IP address. Please refer to the posting -

Printing BaaN Device using Printer's IP Address (http://www.baanboard.com/baanboard/showthread.php?s=&threadid=5353&highlight=print)

learner
24th January 2003, 07:41
Hello Np Rao,
Actually this IP Address things is working fine 3-4 days back and we have been doing it since very long.

and even till date it works fine with Device Queue session where i Repeat the Request.

Paul P
24th January 2003, 08:17
Dear learner,

Are you sure the first line on the error message is

Process 18: Error : Read Row Error 506 on ttadv330900 (error 0)

and not

Process 18: Error : Read Row Error 506 on ttadv330000 (error 0)

?

Rgds,
Paul

learner
24th January 2003, 11:14
Yaah I am 100 % sure.

Paul P
25th January 2003, 03:07
Dear learner,

ttadv330 should not exist outside company 000. Hence, if a program is looking for it in another company (in your case, in company 900) then there's something wrong, probably because of a bad or badly installed patch. Did you happen to install any patches around 4-5 days ago, i.e. when the device stopped working?

Rgds,
Paul