aldendata
31st October 2002, 15:22
I cant access to session for maintains parameters. When I try to do that I got following message.
Cannot start session. Audit trail for table tcmcs000 is not switched on in session (Assign tables to database) ttadv4111m000
James
31st October 2002, 17:23
Hi aldendata,
Is this a new Baan instance?
Have you run "Load Mandatory Tables for Audit" in Assign Tables to Database?
evertsen
31st October 2002, 18:05
Using this session, go to special menu and then Load Mandatory Tables for Audit and then Convert to Runtime.
aldendata
1st November 2002, 09:56
I tried, but I still cant access to session for maintain parameters.
evertsen
1st November 2002, 17:23
As I recall, there was a bug where the tables were not assigned correctly. Go into ttaad4111m000 and make sure the parameter tables are actually assigned to the database with audit. The last time I ran Load Mandatory Tables for Audit I ended with parameter tables without audit and every other table with audit! and had to switch them manually. Also, which session specifically are you trying to access?
aldendata
5th November 2002, 17:58
I got help from Baan support.
I have installed BAAN on SQL7 database. But on the server I have two different database, SQL and INFORMIX. When I made Convert to Runtime DD system changed contents of file tabledef6.1. When I deleted information related to INFORMIX in tabledef6.1 file , everything start to work properly.