kplbhll
21st October 2008, 14:39
Dear All ,
when i try to open the session " Generate Maintainance plan"
it shows an error * Conversion factor between base unit in MCS parameters & unit for years not present.*

Pls. help me out for solving this problem.

nishant
22nd October 2008, 11:35
Dear Mr. Kapil Bhalla,

Just go to the session "tcmcs0500m000" and check the unit for "TIME", then in Conversion Factors Session "tcibd0103m000" define a general conversion factor against this TIME Unit for all the time units you have used in your calendar.

Regards,
Nishant Verma
nishant2180@gmail.com

kplbhll
23rd October 2008, 07:33
Dear Nishant,
The problem is solved .Thanks a lot for the solution.