bh_vfp
11th April 2002, 15:29
In several sessions we get the message ttstps0108 "Quantity not allowed".

One of the sessions is tdpur4101s000. If we use article 60030999 then the default quantity ordered is tdpur041.oqua is retrieved from tiitm001.mioq. After tabbing the message ttstp0108 "Ordered not allowed"

If we look with ttaad4500 in tiitm001 there is for example a quantity of 2400 in tiitm001.mioq, but when we look wit a sql tool in the sql-database the value is 2399,99999999999.

Does anyone know if there is a relation between the difference between ttaad4500/SQL7.0 and de message ttstps0108 ??

Bas

shantays
11th April 2002, 17:06
Hi ,

Are you using the latest portingset for BaanIVc4. If not, which one are you using.

Shanta

bh_vfp
11th April 2002, 17:12
Shanta,

We have portingset 6.1c.06.03 and are using Win2000.

Bas

OmeLuuk
15th April 2002, 10:43
This dll is known to not round data, be sure you have solution (first 118340 and then) 119177 installed...

bh_vfp
15th April 2002, 11:10
OmeLuuk,

These solution were already installed.

Thanks for your reply,

Bas