danielv
15th March 2005, 22:12
I had a test version of webtop on a test environment running build: GY0106,
but recently I'm been getting an error message when login in:
3GL programming error for DsNlinkObject: Object 0 not found in process ottstpstdlib (pid = 2)

Then if I go into details the first line I get is:
Call to otgintwebtop.getusernode failed. Could not get root nodes.

Now, if I go into the Webtop administration console and webtop admin pages/diagnostics and within the webtop framework properties I can see that the Log root level is set to ERROR

Does anyone knows what this setting means and how to fix it/change it?
It would be nice to get a screenshot of the webtop framwork properties page.

Thanks

Han Brinkman
16th March 2005, 13:07
I get similair messages if my DEM setup is not correct.

are you using BaanIV or BaanV?

Regards,

danielv
16th March 2005, 19:43
We are using Baan IV.
Even though we have DEM I don't have it setup for this user.

Could you provide screenshot of webtop framework properties?

thanks

danielv
16th March 2005, 19:55
Hans,
I just disable Baan Process Browser & Baan Workflow in the maintain user data and I was able to get in..
I think my DEM models need to be validated


thanks

Daniel

Han Brinkman
17th March 2005, 12:01
That's what i have to do as well if I give my users access via the menu browser.

I have noticed that using webtop/DEM is more restricted, you need to make sure that all is defined well in DEM.

Rgrds,
Han