BhushanPatil
30th April 2015, 14:58
Hi All,
In Infor ERP LN FP7, the Conversion Factor is maintained for the Itemcode between two different units. Now the conversion Factor needs to be changed.
If it is possible then please let me know the process by which the same can be done.
Thanks.
Bhushan
bhushanchanda
30th April 2015, 15:29
Hi,
AFAIK, creating a new unit to the related items is the best and safest way to handle the situation. Changing/Editing the conversion factor might lead to data corruption due to existing transactions for the item.
But for LN FP7 onwards a new functionality has been introduced, which allows to modify conversion factors for items or item groups that have already been approved. Via the specific menu the session "Update Approved Conversion Factor" (tcibd0103s100) can be started and a new value can be entered. This is possible as long as the section "Usage in Inventory Data (blocking)" does not indicate the usage of the item on inventory level.
Refer KB#1043947
BhushanPatil
7th May 2015, 10:16
Thank you Bhushan.
Specifically the second part of your explanation helped me to understand the issue better and solve the query raised.